Investigating the Mechanism of Button Battery Burns

Button batteries present a major risk in safety, due to burns and complications if ingested. This investigation examined the mechanism of button battery burns by modelling the electrochemical environment that develops when a battery contacts moist biological tissue. Button batteries generate hydroxide ions at the cathode through a reduction reaction, creating a highly alkaline environment capable of causing rapid liquefactive necrosis. To simulate this process, slices of ham were exposed to electrolysis at voltages ranging from 2V to 10V, with mass loss used as an indicator of tissue degradation. A CR2032 button battery was included as a comparison. Results showed a general trend of increasing mass loss with higher voltage, with the greatest degradation occurring at 8V (0.48 g). The button battery produced an equivalent mass loss, reinforcing the danger of ingestion. Reliability was supported through repeated trials, though limitations such as tissue variability, heat generation, and saline evaporation may have influenced results. Overall, the experiment demonstrated that even low voltages can cause measurable tissue damage within minutes, highlighting the urgency of early intervention when ingestion.

Lara P., Sydney – Parramatta

Inquiry – Years 7 to 8

NSW